Department of Surgery, Rajavithi Hospital, College of Medicine, Rangsit University, Bangkok, Thailand.
ABSTRACT
Objective: To study the outcomes of endoscopic ultrasound-guided gastroenterostomy (EUS-GE) using lumen- apposing metal stent (LAMS) in patients with benign and malignant gastric outlet obstruction (GOO).
Materials and Methods: This single-center study retrospectively reviewed the medical records of benign and malignant GOO patients who underwent EUS-GE between May 2019 and September 2023. We evaluated the technical success, adverse events related to the techniques used, clinical success, and recurrence and reintervention rates.
Results: A total of twelve patients who underwent three different EUS-GE techniques were included in this study. The first method was the direct over-the-guidewire technique, the second was the wireless-freehand method, and the third was modified endoscopic ultrasound-guided double-balloon occluded gastroenterostomy bypass (M-EPASS). All 3 techniques used preloaded oroenteral catheters in combination. Technical success was achieved in 83.3% (10/12) of patients, and there were 16.6% (2/12) failures due to misdeployment. One (8.3%) severe adverse event occurred resulting in peritonitis during the direct over-the-guidewire method. The second failure, which ensued after use of the wireless-freehand technique, achieved successful stent deployment at the second attempt without any complications. Clinical success was 100% (11/11), and mean follow up was 6.2 months. There was one (9.1 %) incidence of recurrence at 12-month follow up.
Conclusion: EUS-GE is effective in the management of GOO, and the wireless-freehand and M-EPASS techniques in combination with oroenteral catheters should be the technique of choice in term of safety and efficacy.
Keywords: EUS-guided gastroenterostomy; lumen-apposing metal stent; gastric outlet obstruction; benign; malignant (Siriraj Med J 2024; 76: 174-181)
INTRODUCTION
Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) using lumen-apposing metal stent (LAMS) has been used as an alternative treatment for malignant gastric outlet obstruction (GOO). It has been shown by many studies to achieve good clinical outcomes and to result in fewer complications compared to surgical gastrojejunostomy; furthermore, it requires less reintervention compared to
endoscopic enteral stenting. Recent publications have investigated the use of this procedure for the treatment of benign GOO and reported similar outcomes. However, the technical success and adverse events reported in many studies still vary, probably because of the use of various unstandardized techniques, the different equipment utilized for the procedure in each center, and the small number of patients in most of the studies. With regard
Corresponding author: Kannikar Laohavichitra E-mail: niphangnga@yahoo.com
Received 10 January 2024 Revised 7 February 2024 Accepted 15 February 2024 ORCID ID:http://orcid.org/0000-0002-7546-1691 https://doi.org/10.33192/smj.v76i4.267242
All material is licensed under terms of the Creative Commons Attribution 4.0 International (CC-BY-NC-ND 4.0) license unless otherwise stated.
to benign GOO, data is still limited with respect to long- term placement of the stent and attendant complications, the need for a stent, and the proper timing of its removal. Our study retrospectively reviewed the use of EUS-GE in malignant and benign GOO using electrocautery- enhanced LAMS in order to investigate its outcomes in terms of technical success, adverse events following each technique, clinical success, and recurrence and reintervention rates at long-term follow up.
MATERIALS AND METHODS
This research was approved by the Institutional Review Board (code:66164). The medical records were retrospectively reviewed of individuals who underwent EUS-GE between May 2019 and September 2023, and 12 patients were included in the study. The nature of the GOO was confirmed by the results of esophagogastroduodenoscopy (EGD) and/or abdominal CT scan, with GOO score of 0-1 (Table 1).1 The inclusion criteria for malignant obstruction were unresectable diseases and benign GOO unfit for surgery. The exclusion criteria were massive ascites.
All patients underwent general anesthesia or deep sedation with propofol, and antibiotic prophylaxis was administered preoperatively. The procedures were performed using a 15x10 mm. or 20x10 mm in diameter LAMS with electrocautery-enhanced delivery system called Hot AXIOSTM Stent (Boston Scientific Corp., Marlborough, MA, United States) which facilitated trans-gastric puncture and stent deployment in a single step.
Gastroscopy with gastric irrigation was performed prior to starting EUS-GE with the aim of eliminating gastric content. Preloaded devices included nasobiliary tube; balloon catheter for stone extraction or nasojejunal tube feeding over the 0.025 or 0.035-inch guidewire beyond
the tumor; and an oroenteral tube with an endoscopy irrigation pump to continuously infuse the mixed solution of normal saline combined with contrast medium and a small amount of blue dye, such as indigo carmine or methylene blue, during the EUS-GE procedure in order to facilitate the visualization of enteral segment by EUS. One of three EUS-GE techniques was then employed.
IN) was advanced over a 0.025 or 0.035-inch guidewire
and positioned at the ligament of Treitz for temporary
TABLE 1. The gastric outlet obstruction scoring system
Level of oral intake | Score |
No oral intake | 0 |
Liquids only | 1 |
Soft solids | 2 |
Low-residue or full diet | 3 |
occlusion of the duodeno-jejunal segment to prevent rapid draining of the infused fluid from affecting the prolonged visualization of the target enteral loop in order to facilitate the EUS-GE procedure (Fig 1 & 2). The LAMS with electrocautery-enhanced delivery system was then deployed using the wireless-freehand technique.
After the LAMS was deployed, the correct position of the stent was confirmed by passing the mixed solution through the stent into the gastric lumen. All patients were allowed a fluid diet the day after the procedure if
Fig 1. Double balloon catheter technique Fig 2. Double balloon catheter technique: the balloon extraction catheter and stent graft balloon catheter (arrows)
Medical illustrator: Tanyaporn Chantarojanasiri, M.D.
no signs of perioperative complications were observed, and they progressed to a full diet on the following day. Technical success was defined as the correct positioning of the stent deployment. Adverse events were recorded as perforation, bleeding, peritonitis, and cardiopulmonary adverse events from sedation. Clinical success was defined as improvement in GOO score from 0-1 to 2-3. Recurrence was defined as a decrease in the
GOO score to 0-1 after earlier improvement.
RESULTS
A total of 12 consecutive patients underwent EUS-GE. Their mean age was 57.8 years (range 30-82 years), and 10 of them were female. Nine had malignant etiologies, 2 had benign conditions, and one had an uncertain diagnosis. The majority of the obstructions were located at the 1st-3rd parts of the duodenum with two cases of pyloric obstruction. Preoperative GOO scores were 0-1, and the duration of the presence of obstruction varied from 0.5-6 months (Table 2).
All patients successfully demonstrated enteral segment after preloading of an oroenteral catheter and continuous infusion of the mixed solution. Ten patients had technical success (Table 3). The first technical failure occurred as a result of misdeployment of the first flange into the peritoneal cavity, after which the patient developed peritonitis immediately, probably due to improper preoperative stomach preparation resulting in severe contamination of the abdominal cavity. She underwent laparotomy in order to decontaminate the infected material and then had surgical gastrojejunostomy. She had a good recovery and was discharged about a week later. The second technical failure (patient No.9) had stent misdeployment at the first attempt under the wireless-free hand technique, but a stent
was successfully deployed at the second attempt using the same technique in the same session after endoscopic closure of the gastric defect had been performed with a clip, and no peritonitis developed. In summary, the technical success of the wireless-freehand technique was 75% (3/4), while the M-EPASS approach achieved 100% (6/6), and the overall technical success was 83.3% (10/12). Unfortunately, one success was achieved with an unknown technique because no data were recorded, while the direct over-the-guidewire technique achieved no technical success 0% (0/1).
All eleven patients who successfully received EUS-GE attended final follow up at a mean of 6.2 months (range 0.75-22 months), and they all achieved clinical success and had improved their GOO score to 2-3. The longest stent patency was recorded at 20 months with a 10x20 mm diameter stent. Only one patient (patient number 2) developed recurrent obstructive symptoms from tissue ingrowth, with decreased GOO score down to 0 at the 12-month follow up after also receiving a 10x20 mm diameter stent. After failing to respond to endoscopic balloon dilation, he received an additional LAMS size 10x20 mm (stent in stent) with the use of a therapeutic gastroscope after the tissue ingrowth was burned using forced argon plasma coagulation of 60 watts. The stent patency was observed endoscopically and intraoperative contrast medium from the gastric site was found to have passed through the stent into the jejunum (Fig 3). The patient had good response with GOO score 3 at the last 5-month follow up. The patient with SMA syndrome (patient number 11) had endoscopic stent removal after 5-month follow up and regained weight. Contrast study showed improvement in the duodenal obstruction, and there were no adverse events during stent removal.
TABLE 2. Patient characteristics
Patient | Age | Gender | Co- morbidities | Etiology of GOO | Location of obstruction | Duration of obstruction | Pre- operative |
(months) | GOO score | ||||||
1 | 72 | Female | CHF | Peptic stricture | Pylorus | 2 | 1 |
2 | 30 | Male | None | Hilar cholangiocarcinoma | 1st-2nd part duodenum | 5 | 0 |
3 | 56 | Female | None | Carcinoma of the uncinate process of the pancreas | 2nd part duodenum | 1 | 0 |
4 | 71 | Female | DM, HT, DLP | Distal cholangiocarcinoma | 1st-2nd part duodenum | 0.5 | 0 |
5 | 47 | Female | None | Breast cancer with pancreatic metastasis | 1st-2nd part duodenum | 2 | 0 |
6 | 51 | Female | None | Right-sided colon cancer | Pylorus to 2nd pa duodenum | rt 0.5 | 0 |
7 | 59 | Female | None | Gallbladder cancer | 1st-2nd part duodenum | 3 | 0 |
8 | 62 | Male | None | Carcinoma of the head of pancreas | 2nd-3rd part duodenum | 3 | 1 |
9 | 71 | Female | None | Carcinoma of the head of pancreas | 2nd part duodenum | 2 | 0 |
10 | 58 | Female | None | Carcinoma of the uncinate process of the pancreas | 1st-2nd part duodenum | 3 | 1 |
11 | 35 | Female | DM, neurogenic bladder, acute kidney injury, urinary tract infection | SMA syndrome | 2nd -3rd part duodenum | 6 | 1 |
12 | 82 | Female | HT, CKD, DLP, Compression fracture T11 | Duodenal obstruction unidentified cause | 2nd part duodenum | 1 | 0 |
TABLE 3. Patient and procedural characteristic
Patient | Techniques | Stent size (mm) | Technical success | Adverse events | LOS (day) | Post-op. GOO score | Clinical success | Recurr. | F/U (Mo.) |
1 | Direct over-the- guidewire | 10x15 | No | misdeployment & Peritonitis | 10 | - | - | - | - |
2 | Wireless-freehand | 10x20 | Yes | No | 8 | 3 | Yes | Yes | 22 |
3 | Wireless-freehand | 10x20 | Yes | No | 19 | 3 | Yes | No | 20 |
4 | M-EPASS | 10x15 | Yes | No | 12 | 3 | Yes | No | 7 |
5 | M-EPASS | 10x20 | Yes | No | 8 | 2 | Yes | No | 5 |
6 | Missing data | 10x20 | Yes | No | 18 | 3 | Yes | No | 1 |
7 | Wireless-freehand | 10x20 | Yes | No | 13 | 3 | Yes | No | 4 |
8 | M-EPASS | 10x20 | Yes | No | 29 | 3 | Yes | No | 1 |
9 | Wireless-freehand | 10x20 | No | misdeployment | 11 | 3 | Yes | No | 4 |
10 | M-EPASS | 10x20 | Yes | No | 12 | 3 | Yes | No | 0.75 |
11 | M-EPASS | 10x20 | Yes | No | 72 | 2 | Yes | No | 5 |
12 | M-EPASS | 10x20 | Yes | No | 9 | 3 | Yes | No | 2 |
Fig 3. a. Previous stent occlusion, b. Deploying the second stent (stent in stent technique) using a therapeutic gastroscope, c. Endoscopic image showing patency of the stent after deploying the second stent, d. Contrast study showing good patency of the stent.
DISCUSSION
Surgical gastrojejunostomy, both open and laparoscopic, was a modality of treatment for malignant GOO which had long-term patency but entailed high morbidities because of patients being unfit for surgery. Endoscopic duodenal stenting replaced it as a minimally invasive treatment which yielded benefits in terms of rapid relief of obstructive symptoms and shorter hospital stay, but this modality resulted in high rates of recurrent obstruction due to tumor ingrowth with the need for reintervention, and it was therefore proposed for the treatment of choice only in cases with a life expectancy of shorter than 3 months.2 EUS-GE has recently become the preferred alternative treatment with many multicenter studies, reviews, systematic reviews and meta-analyses demonstrating that it was minimally invasive, had rapid efficacy and longer patency than endoscopic duodenal stenting, and had similar patency but fewer adverse events compared to surgery.2-5
Earlier designs of the deployment system of LAMS had no cautery tip, so that the EUS-GE procedure involved multiple steps, such as transmural puncture, placement of a guidewire, and needle tract dilation using a balloon or cautery dilator catheter followed by LAMS with over-the- guidewire deployment. The complexity of the procedure affected technical success as well as adverse events, with earlier publications reporting technical success ranging from 90-92 %6,7; however, some patients required salvage procedures, such as bridging, using fully-covered self- expandable metal stents (FCSEMS) or utilizing LAMS via the natural orifice transluminal endoscopic surgery (NOTES) technique, to correct the misplaced stents. One study also reported major adverse events (11.5%) from peritonitis, bleeding and abdominal pain resulting in the need for laparotomy.7
Recently, an electrocautery-enhanced LAMS has been developed and is widely used for EUS-GE in order to allow multi-step stent placement in a single device which decreases operative time and appears to increase technical success and minimize adverse events. On
W. et al8 reported EUS-GE using cautery-enhanced LAMS in a multi-center study. Various techniques were used and demonstrated a technical success rate of 92% with just 8% of moderate adverse events resulting from mis- deployment. With this in mind, our center favored the use of the electrocautery-enhanced LAMS to simplify the technical steps, and we achieved similar overall technical success of 83.3% (range 75-100% for each technique) with just one (8.3%) severe adverse event.
One major concern in performing EUS-GE regards the need for improvement of the method used for stent
deployment in order to improve technical success and minimize complications. The technique has been developed through various clinical trials and can be classified into 2 types: the direct over-the-guidewire technique and the wireless-freehand insertion method.9-11
The direct over-the-guidewire method, with or without pre-procedural saline infusion into the small bowel loop, requires a trans-gastric puncture using a 19-gauge needle to enable preloading of a guidewire into the targeted loop and a one-step exchange to the electrocautery-enhanced LAMS system before the stent is deployed. Physicians in some clinical trials have preferred using a balloon-assisted (targeted) method involving preloading a 15-20 mm. stone-retrieval balloon or balloon dilation catheter over the guidewire into the targeted enteral loop before making a trans-gastric puncture of the inflated balloon to help confirm that the correct enteral loop has been punctured before continuing with the next step of deploying the LAMS. Chen YI et al.12 reported that these two techniques seem to be comparable in terms of technical success and safety12 The disadvantage of the over-the-guidewire technique is that it requires more exchanges and carries a risk of mis-deployment as a result of rapid fluid migration from the target loop10, which can push the stent during the procedure.11
The wireless-freehand insertion technique requires some devices to assist with fluid administration into the target intestinal loop to achieve good visualization under EUS. Placing an oroenteral catheter used to be the most popular technique, as it was easy to find suitable catheters. Insertion of a specially designed double- balloon enteric tube (Tokyo Medical University type; Create Medic Co., Ltd, Yokohama, Japan), called an endoscopic ultrasonography-guided double balloon- occluded gastrojejunostomy bypass (EPASS), across the obstruction point was another option. The additional procedure prior to insertion of the LAMS system involved inflating the two balloons with contrast medium and infusing fluid into the small bowel segment between the two balloons to facilitate stent placement. However, these specially designed catheters are not commercially available worldwide. Lately, many studies’ authors have advocated the use of the wireless-freehand insertion technique, as they believe it to be superior to the direct over-the-guidewire method in terms of safety and efficacy because of its high technical success of 98-100% and its low incidence of adverse events (2.8-7%) without severe complications13-15; on the other hand, others have claimed that the EPASS procedure potentially enhances technical success and safety.16,17 Basha J, et al.18 reported that EUS-GE with the EPASS technique was also feasible
in patients presenting with ascites, stating technical success of 91.6%, clinical success of 83.3 and 0% adverse events, and these results were not significantly different from those achieved in patient without ascites.
Mario A, et al.19 developed a technique to mimic EPASS by using two vascular balloons, which they called a modified approach to EUS-guided double-balloon- occluded gastroenterostomy (M-EPASS), to facilitate EUS-GE. The technical success rate was 91%, clinical success was 80%, and there was just one adverse event due to stent migration. The M-EPASS technique seems to be comparable with EPASS, but the latter has the advantage of using commercially available accessories. Over 20 single-arm studies have been published about EUS-GE in malignant GOO, with technical success varying between 80-100%, clinical success 73-95% and serious adverse events numbering approximately 3-6%.20 The results achieved in our center seem comparable with overall technical success. The M-EPASS technique and the wireless freehand combined with oroenteral catheter were 83.3%, 100% and 75% respectively. One incidence (8.3%) of a severe adverse event from the direct over-the-guidewire technique persuaded us to change our technique of preference to the wireless-freehand method, and we are now becoming more comfortable with the M-EPASS technique. The high incidence of mis-deployment of 16.7% (2/12) is probably related to the learning curve associated with becoming familiar with the procedure, as proficiency is normally achieved
after completion of 7-25 procedures.20
With regard to clinical success associations with stent size and patency, recent studies have recommended that a large luminal diameter with the 20-mm LAMS is technically feasible and more likely to achieve tolerance of a soft solid or complete diet.15,20-21 This recommendation is in keeping with the findings of our study, in which the majority of stents used for EUS-GE were 20-mm, and the patients still had GOO score of 2-3 in the mean follow up period of 6.2 months (range 0.75-22 months), with longest patency of about 20 months and one stent occlusion from tissue ingrowth at 12-month follow up. Only two patients received 15-mm stent: one of these had technical failure due to mis-deployment, while the other still had good GOO score at 7-month follow up. Some retrospective studies have reported the use of
EUS-GE specifically for benign conditions, such as peptic stricture, anastomotic stricture, duodenal hematoma, acute/ chronic pancreatitis, pancreatic pseudocyst/walled-off pancreatic necrosis, superior mesenteric artery syndrome, and caustic stricture22,23 They demonstrated that it was a promising modality for benign GOO, especially for cases
which were unlikely to respond to dilation therapy or in cases when this technique was not possible. Physicians were able to avoid surgery for GOO in 83.3% of cases.23 The technical and clinical success rates were similar to those of patients with malignant conditions. The most commonly reported adverse events occurred mostly in mild conditions such as abdominal discomfort and stent mis-deployment, but there were also some severe adverse events. Chen YI et al.22 reported gastric leak after elective stent removal which needed surgical intervention, and James TW et al.23 reported bleeding from a gastric ulcer at the anastomotic site 2 days after the procedure. There was also a case of small bowel obstruction resulting from LAMS migration 1 year after deployment which required laparotomy for removal of the stent, while in another patient, the gastrojejunostomy stent was found to have transversed from the stomach through the colon and into the jejunum but without contrast leakage. Recurrence of GOO while the stent was in place was mostly caused by food impaction, and this was successfully managed by endoscopic removal, but there were some cases which needed surgical intervention.22,23 James TW et al.23 recommended that the stent stay in place for a mean time of 8.5 months and should be removed after improvement in GOO to avoid complications from the stent; however, some recurrent GOO still occurred after stent removal. Our study showed one good response after EUS-GE in a benign condition (SMA syndrome), with the patient having the stent removed at 5-month follow up. Generally in case of malignant, LAMS will be reintervention when re-obstructive symptoms occur. In case of benign condition apart from re-obstruction, Elective exchange should be considered to avoid troublesome of tissue ingrowth and overgrowth. Six month interval is preferable by expert endosonographers.24
CONCLUSION
EUS-GE is effective in the management of GOO, and the wireless freehand method combined with the M-EPASS technique or oroenteral catheter should be the technique of choice in term of safety and efficacy. However, a larger prospective study is needed to further evaluate this technique in treating both benign and malignant GOO.
REFERENCES
Adler DG, Baron TH. Endoscopic Palliation of Malignant Gastric Outlet Obstruction Using Self-Expanding Metal Stents: Experience in 36 Patients. Am J Gastroenterol. 2002;97(1): 72-8.
Troncone E, Fugazza A, Cappello A, Blanco GDV, Monteleone G, Repici A, et al. Malignant gastric outlet obstruction: Which is
the best therapeutic option? World J Gastroenterol. 2020;26(16): 1847-60.
Miller C, Benchaya JA, Martel M, Barkun A, Wyse JM, Ferri L, et al. EUS-guided gastroenterostomy vs. surgical gastrojejunostomy and enteral stenting for malignant gastric outlet obstruction: a meta-analysis. Endosc Int Open. 2023;11(7):1-13.
Miranda MP, Tyberg A, Poletto D, Toscano E, Gaidhane M, Desai AP, et al. EUS-guided Gastrojejunostomy Versus Laparoscopic Gastrojejunostomy An International Collaborative Study. J Clin Gastroenterol. 2017;5:896-9.
Bomman S, Ghafoor A, Sanders D, Jayaraj M, Chandra S, Krishnamoorthi R. Enoscopic ultrasound-guided gastroenterostomy versus surgical gastrojejunostomy in treatment of malignant gastric outlet obstruction: Systematic review and meta-analysis. Endosc Int Open. 2022;10:361-8.
Khashab MA, Kumbhari V, Grimm IS, Ngamruengphong S, Aguila G, Zein ME, et al. EUS-guided gastroenterostomy: the first U.S. clinical experience (with video). Gastrointest Endosc. 2015;82:932-8.
Tyberg A, Miranda MP, Ocaña RS, Peñas I, Serna C, Shah J, et al. Endoscopic ultrasound-guided gastrojejunostomy with a lumen-apposing metal stent: a multicenter, international experience. Endosc Int Open. 2016;4:276-81.
On W, Huggett MT, Young A, Pine J, Smith AM, Tehami N, et al. Endoscopic ultrasound guided gastrojejunostomy in the treatment of gastric outlet obstruction: multi-center experience from the United Kingdom. Surg Endosc. 2023;37(3):1749-55.
Tonozuka R, Tsuchiya T, Mukai S, Nagakawa Y and Itoi T. Endoscopic Ultrasonography-Guided Gastroenterostomy Techniques for Treatment of Malignant Gastric Outlet Obstruction. Clin Endosc. 2020;53:510-8.
Stefanovic S, Draganov PV, Yang D. Endoscopic ultrasound guided gastrojejunostomy for gastric outlet obstruction. World J Gastrointest Surg. 2021;13(7):620-32.
Monino L, Robles E, Gonzalez JM, Snauwaert C, Alric H, Gasmi M, et al. Endoscopic ultrasound-guided gastroenterostomy with lumen-apposing metal stents: a retrospective multicentric comparison of wireless and over-the wire technique. Endoscopy. 2023;55: 991-99.
Chen YI, Kunda R, Storm AC, Aridi HD, Thomson CC, Neito J, et al. EUS-guided gastroenterostomy: a multicenter study comparing the direct and balloon-assisted techniques. Gastrointest Endosc. 2018;87:1215-21.
Park KH, Rosas US, Liu QY, Jamil LH, Gupta K, Gaddam S, et al. Safety of teaching endoscopic ultrasound-guided gastro-enterostomy (EUS-GE) can be improved with standardization
of the technique. Endosc Int Open. 2022;10:1088-94.
Nguyen NQ, Hamerski CM, Nett A, Watson RR, Rigopoulos M, Binmoeller KB. Endoscopic ultrasound-guided gastroenterostomy using an oroenteric catheter-assisted technique: a retrospective analysis. Endoscopy. 2021;53:1246-9.
Sobani ZA, Paleti S, Rustagi T. Endoscopic ultrasound-guided gastroenterostomy using large-diameter (20 mm) lumen apposing metal stent (LLAMS). Endosc Int Open. 2021; 09:895- 900.
Itoi T, Baron TH, Khashab MA, Tsuchiya T, Irani S, Dhir V, et al. Technical review of endoscopic ultrasonography-guided gastroenterostomy in 2017. Dig Endosc. 2017;29(4):495-502.
Itoi T, Ishii K, Ikeuchi N, Sofuni A, Gotoda T, Moriyasu F, et al. Prospective evaluation of endoscopic ultrasonography-guided double-balloon-occluded gastrojejunostomy bypass (EPASS) for malignant gastric outlet obstruction. Gut 2016;65(2):193-5.
Basha J, Lakhtakia S, Yariagadda R, Nabi Z, Gupta R, Ramchandani M, et al. Gastric outlet obstruction with ascites: EUS-guided gastro-enterostomy is feasible. Endosc Int Open. 2021;9(12): E1918-23.
Marino A, Bessissow A, Miller C, Valenti D, Boucher L, Chaudhury P, et al. Modified endoscopic ultrasound-guided double-balloon-occluded gastroenterostomy bypass (M-EPASS): a pilot study. Endoscopy. 2022;54:170-2.
Pavert YL, Moons LMG, Bogte A, Vleggaar FP. Innovations in the Treatment of Gastric Outlet Obstruction: Is this the Era of Enodscopic Ultrasonography-Guided Gastroenterostomy? Curr Treat Options Gastro 2023. DOI 10.1007/s11938-023- 00417-1.
Bejjani M, Ghandour B, Subtil JC, Moreno BM, Sharaiha RZ, Watson RR, et al. Clinical and technical outcomes of patients undergoing endoscopic ultrasound-guided gastroenterostomy using 20-mm vs. 15-mm lumen-apposing metal stents. Endoscopy. 2022;54:680-7.
Chen YI, James TW, Agarwal A, Baron TH, Itoi T, Kunda R, et al. EUS-guided gastroenterostomy in management of benogn gastric outlet obstruction. Endosc Int Open. 2018;6(3): E363-8.
James TW, Greenberg S, Grimm IS, Baron TH. EUS-guided gastroenteric anastomosis as a bridge to definitive treatment in benign gastric outlet obstruction. Gastroentest Endosc. 2020;91(3):537-42.
Magahis PT, Salgado S, Westerveld D, Dawod E, Carr-locke DL, Sampath K, et al. Prefered techniques for endoscopic ultrasound-guided gastroenterostomy: a survey of expert endosonographer. Endosc Int Open. 2023;11:E1035-45.