Evaluation of Leukocyte-Depleted Blood Components from Citrate Phosphate Dextrose / Saline Adenine Glucose–Mannitol Quadruple Blood Bag with an Integrated Leukocyte Filter

Authors

  • Ubonwon Charoonruangrit Department of Clinical Pathology, School of Medicine, Mae Fah Luang University, Chiang Rai, Thailand 57100
  • Panwadee Tejawong Blood Bank Service, Division of Clinical Pathology, Medical Center Hospital, Mae Fah Luang University, Chiang Rai, Thailand 57100
  • Jutamas Sangsuemoon Blood Bank Service, Division of Clinical Pathology, Medical Center Hospital, Mae Fah Luang University, Chiang Rai, Thailand 57100
  • Phuping Pratchaya Blood Bank Service, Division of Clinical Pathology, Medical Center Hospital, Mae Fah Luang University, Chiang Rai, Thailand 57100

Keywords:

Leukocyte-depleted blood components, Leukocyte-depleted packed red cells, Leukocyte-depleted fresh frozen plasma, Residual white blood cells, Quality control of blood components

Abstract

Background: Leukocyte-depleted blood components are widely used to reduce transfusionrelated adverse reactions associated with residual leukocytes. When a new blood bag system is introduced into routine practice, evaluation of the quality of the resulting blood components is necessary to ensure compliance with the National Standards Criteria.

Objectives: This study aimed to evaluate leukocyte-depleted blood components, including leukocyte-depleted packed red cells in additive solution (LDPRC) and leukocyte-depleted fresh frozen plasma (LDFFP), prepared using a citrate phosphate dextrose/saline adenine glucose- mannitol (CPD/SAG-M) quadruple blood bag with an integrated leukocyte filter, and to evaluate the blood components quality according to the National Standards Criteria.

Materials and Methods:This descriptive evaluation study was conducted at the Blood Bank, Division of Clinical Pathology Mae Fah Luang University Medical Center Hospital. Whole blood was collected using CPD/SAG-M quadruple blood bags with an integrated leukocyte filter and processed into LDPRC and LDFFP. Evaluation was done in accordance with the National Standards Criteria for approval of validation of blood component characteristic, including component volume, hemoglobin content, residual white blood cell (rWBC) count,
and hemolysis during storage. Residual WBC enumeration was performed using an automated hematology analyzer in body fluid mode based on flow cytometric principles.

Results:All LDPRC units met the criteria for residual leukocyte content and other parameters throughout the storage period. Hemolysis remained within specified limits up to 42 days of storage. LDFFP units also complied with the criteria. Analysis of factor VIII activity is currently in progress.

Conclusions:Leukocyte-depleted blood components prepared using the evaluated CPD/SAG-M quadruple blood bag with an integrated leukocyte filter met the National Standards Criteria, supporting the suitability of this system for routine blood component preparation in a hospital-based blood bank.

References

National Blood Centre, Thai Red Cross Society. Standards for Blood Banks and Transfusion Services. 5th ed. Bangkok: National Blood Centre, Thai Red Cross Society; 2024. ISBN: 978-616-8345-02-3.

National Blood Centre, Thai Red Cross Society. Physician’s Manual for Rational Use of Blood and Blood Components. 2nd ed. Bangkok: National Blood Centre, Thai Red Cross Society; 2023. ISBN: 978-616-8212-84-4.

World Health Organization. Educational modules on clinical use of blood. Geneva: World Health Organization; 2021. ISBN: 978-92-4-003373-3 (electronic), 978-92-4-003374-0 (print).

Cohn CS, Delaney M, Johnson ST, Katz LM, editors. Technical manual. 21st ed. Bethesda (MD): AABB; 2023.

European Directorate for the Quality of Medicines & HealthCare (EDQM). Guide to the preparation, use and quality assurance of blood components: appendix to Recommendation No. R (95) 15. 22nd ed. Strasbourg: Council of Europe; 2025.

Henzhen Mindray Bio-Medical Electronics Co., Ltd. BC-6200 automated hematology analyzer: operator’s manual. Shenzhen: Shenzhen Mindray Bio-Medical Electronics Co., Ltd.; 2018.

Arif SH, Yadav N, Rehman S, et al. Study of hemolysis during storage of blood in the blood bank of a tertiary health care centre. Indian J Hematol Blood Transfus. 2017; 33 (4): 598–602. https://doi.org/10.1007/s12288-016-0769-5

Makroo RN, Raina V, Bhatia A, et al. Evaluation of the red cell hemolysis in packed red cells during processing and storage. Asian J Transfus Sci.2011; 5 (1): 15–9.

Downloads

Published

2026-05-04

How to Cite

1.
Charoonruangrit U, Tejawong P, Sangsuemoon J, Pratchaya P. Evaluation of Leukocyte-Depleted Blood Components from Citrate Phosphate Dextrose / Saline Adenine Glucose–Mannitol Quadruple Blood Bag with an Integrated Leukocyte Filter. GMSMJ [internet]. 2026 May 4 [cited 2026 May 5];6(2):93-106. available from: https://he02.tci-thaijo.org/index.php/gmsmj/article/view/280578

Issue

Section

Transfusion Medicine