The Removal of Colors in Non-carbonated Soft Drinks using Granular Activated Carbon for Coliform Bacteria Detection by Sanitary Indicator Medium

Authors

  • Naovarat Srisantisang Graduate Student in Master of Science Programme in Environmental Sanitation, Faculty of Public Health, Mahidol University
  • Pisit Vatanasomboon Department of Environmental Health Science, Faculty of Public Health, Mahidol University
  • Piangchan Rojanavipart Department of Biostatistics, Faculty of Public Health, Mahidol University
  • Pipat Luksamijarulkul Department of Microbiology, Faculty of Public Health, Mahidol University

Keywords:

non-carbonated soft drink, color removal, granular activated carbon, SI medium, coliform bacteria detection, เครื่องดื่มไร้คาร์บอเนต, กำจัดสี, ถ่านกัมมนต์ชนิดเกล็ด, อาหารตรวจเชื้อ, ตรวจโคลิฟอร์มแบคทีเรีย

Abstract

ABSTRACT

This research was designed to study the efficiency of non-carbonated soft drink color removal by using granular activated carbon (GAC) for coliform bacteria detection by SI medium. The conditions established in the study were to use 6 color tones of non-carbonated soft drinks (red, green, purple, blue, orange and yellow) which were removed by using 3 GAC amounts (100, 200, 300 mg per soft drink 1 mL) at two contact times of color removal, 30 and 60 minutes. The results showed that a higher amount of GAC and the increasing of contact time significantly increased color removal efficiency at p-value < 0.05, and that, also, the different color tones of soft drinks significantly affected different color removal efficiencies at p-value < 0.05. The highest color removal efficiency derived from using 300 mg/mL of GAC amount at 60 minutes, but was not the best suitable for every color tone. The best suitable condition of each color tone was selected from the lowest GAC amount and the shortest contact time for the color removal as well as affected the color of SI medium, which was changed to yellow color for a positive result, but was still purple color for a negative result within 24 hours. Using 200 mg/mL of GAC amount at 30 minutes was the best suitable condition for red-green-purple-orange color tones, using 300 mg/mL of GAC amount at 30 minutes was the best suitable condition for yellow color-tone, and using 300 mg/mL of GAC amount at 60 minutes was the best suitable condition for blue color-tone. The validity of coliform bacteria detection by SI medium for these removed-color soft drinks when compared with the standard MPN method were sensitivity value, specificity value and efficiency of test of more than 80%. Thus, GAC can be used to efficiently remove the colors of soft drinks for coliform bacteria detection by SI medium.

Key words: non-carbonated soft drink, color removal, granular activated carbon, SI medium, coliform bacteria detection

Downloads

Issue

Section

Original Articles