Outcomes of Two Implants (Khao Aroi System) Retained Mandibular Overdenture

Authors

  • Leevarakarn S, Wisetsin S, Vichathai W, Nipattasat P, Pakdethanakul C, Khongkhunthian P

Keywords:

Dental implant, Implant stability, Resonance frequency analysis, Bone loss

Abstract

Background : The patients who had lost their natural teeth and have been wearing the full denture for a long time, will have an ill-fitting lower denture. Two implants for retaining a full lower denture can solve the problem.

Objective : The project was to examine the implant’s stability, using the resonance frequency analysis (RFA) method. The marginal bone loss was measured from a panoramic radiograph.

Method : Thirty patients, age over 60, have been chosen from the implant project celebrating King’s 80th Birthday Anniversary on 5 December 2007. All of them were treated at Institute of Dentistry, Department of Medical Services. The study was followed the implant stability and the marginal bone loss around the implants.

Result : The study showed the follow-up 20 ± 8.49 months in average. The implant stability quotient (ISQ) value was 71.24 ± 2.95 and the mean marginal bone loss was 1.52 ± 0.59 millimeters.

Conclusion : Khao Aroi implant system had high stability and the level of bone loss meets the standard success criteria.

References

Mahidol Population Gazette; 2019 [cited 2019 Aug 21]. Available from: http://www.ipsr.mahidol.ac.th/ipsr/Contents/ Documents/Gazette/Gazette2019TH.pdf

Department of Health, Ministry of Public Health. The 6th national oral health survey in Thailand 2006-2007.Dental Health Division, Ministry of Public Health; 2008.

Feine JS, Carlsson GE, Awad MA, Chehade A, Duncan WJ, Gizani S,et al. The McGill consensus statement on overdentures, Montreal, Quebec, Canada, May 24-25, 2002. Int J Prosthodont 2002; 15:413-4.

Thomason JM, Feine J, Exley C, Moynihan P, Muller F, Naert I, et al. Mandibular two implant-supported overdentures as the first choice standard of care for edentulous patients-the York consensus statement. Br Dent J 2009; 207:185-6.

Emami E, Heydecke G, Rompre PH, de Grandmont P, Feine JS. Impact of implant support for mandibular dentures on satisfaction, oral and general health-related quality of life: a meta-analysis of randomized controlled trails. Clin Oral Implants Res 2009; 20:533-44.

Naovaratsophon A, Nipattasat P, Leevarakarn S, editors.Handbook of Implant retained lower denture. 2nd ed. Nontaburi: Institute of Dentistry, Department of Medical Services, Ministry of Public Health; 2008.

Brånemark P-I, Lausmaa J, Ericson L, Thomsen P, Branemark R, Skalak R. Anatomy of osseointegration and the transfer of load. In: fonseca RJ, Davis WH, eds. Reconstructive preprosthetic oral and maxillofacial surgery.Philadelphia.W.B. Saunders Co.; 1995. p. 165-224.

Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont 1998; 11:491-501.

González-García R, Monje F, Moreno-García C. Predictability of the resonance frequency analysis in the survival of dental implants placed in the anterior non-atrophied edentulous mandible. Med Oral Patol Oral Cir Bucal 2011; 16:664-9.

Raghavendra S, Wood MC, Taylor TD. Early wound healing around endosseous implants: a review of the literature. Int J Oral Maxillofac Implants 2005; 20:425-31.

Brånemark P-I, Zarb GA, Albrektsson T (eds.) Tissue- Integrated Prostheses. Chicago: Quintessence; 1985.

Quesada-Garcia MP, Prados-Sanchez E, Olmedo-Gaya MV, Munoz-Soto E, Gonzalez-Rodriguez MP, Vallecillo-Capilla M. Measurement of dental implant stability by resonance frequency analysis: a review of the literature. Med Oral Patol Oral Cir Bucal 2009; 14:538-46.

Atsumi M, Park S-H, Wang H-L. Method used to assess implant stability: current status. Int J Oral Maxillofac Implants 2007; 22:743-54.

Turkyilmaz I, Sennerby L, Tumer C, Yenigul M, Avci M.Stability and marginal bone level measurements of unsplinted implants used for mandibular overdentures: a 1-year randomized prospective clinical study comparing early and conventional loading protocols. Clin Oral Impl Res 2006; 17:501-5.

Yang SM, Shin SY, Kye SB. Relationship between implant stability measured by resonance frequency analysis (RFA) and bone loss during early healing period. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008; 105:12-9.

Meredith N, Shagaldi F, Alleyne D, Sennerby L, Cawley P. The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia. Clin Oral Impl Res 1997; 8:234-43.

Naert IE, Hooghe M, Quirynen M, van Steenberghe D. The reliability of implant-retained hinging overdentures for the fully edentulous mandible: An up to 9-year longitudinal study. Clin Oral Investing 1997; 1:119-24.

Gotfredsen K, Holm B, Sewerin I, Harder F, Hjörting-Hansen E, Pedersen CS, et al. Marginal tissue response adjacent to Astra Dental Implants supporting overdentures in the mandible. Clin Oral Impl Res 1993; 4:83-9.

Cehreli MC, Uysal S, Akca K. Marginal bone level changes and prosthetic maintenance of mandibular overdentures supported by 2 implants: a 5-year randomized clinical trial. Clin Implant Dent Relat Res 2010; 12:114-21.

Naert I, Gizani S, Vuylsteke M, van Steenberghe D. A 5-year randomized clinical trial on the influence of splinted and unsplinted oral implants in the mandibular overdenture therapy. Part I: peri-implant outcome. Clin Oral Impl Res 1998; 9:170-7.

Wismeijer D, van Waas MA, Mulder J, Vermeeren JI, Kalk W. Clinical and radiological results of patients treated with three treatment modalities for overdentures on implants of the ITI Dental Implant System. A randomized controlled clinical trial. Clin Oral Implants Res 1999; 10:297-306.

Tawse-Smith A, Perio C,Pavne AG, Kumara R, Thomson WM. One-stage operative procedure using two different implant systems: A prospective study on implant overdentures in the edentulous mandible. Clin Implant Dent Relat Res 2001; 3:185-93.

Cooper LF, Scurria MS, Lang LA, Guckes AD, Moriarty JD, Felton DA. Treatment of edentulism using Astra Tech implants and ball attachments to retain mandibular overdentures. Int J Oral Maxillofac Implants 1999; 14:646-53.

Naert I, Alsaadi G, van Steenberghe D, Quirynen M. A 10-year randomized clinical trail on the influence of splinted and unsplinted oral implants retaining mandibular overdentures: peri-implant outcome. Int J Oral Maxillofac Implants 2004; 19:695-702.

Sadowsky SJ. Mandibular implant-retained overdentures: a literature review. J Prosthet Dent 2001; 86:468-73.

Mericske-Stern R. Treatment outcomes with implantsupported overdentures: clinical considerations. J Prosthet Dent 1998; 79:66-73.

Ellis JS, Burawi G, Walls A, Thomason JM. Patient satisfaction with two designs of implant supported removable overdentures; ball attachment and magnets. Clin Oral Implants Res 2009; 20:1293-8.

Boerrigter EM, Geertman ME, Van Oort RP, Bouma J, Raghoebar GM, van Wass MAJ, et al. Patient satisfaction with implant-retained mandibular overdentures. A comparison with new complete dentures not retained by implants-a multicenter randomized clinical trial. Br J of Oral and Maxillofac Surg 1995; 33:282-8.

Thomason JM. The use of mandibular implant-retained overdentures improve patient satisfaction and quality of life. J Evid Base Dent Pract 2010; 10:61-3.

Emami E, Heydecke G, Rompré PH, de Grandmont P, Feine JS. The impact of implant support for mandibular dentures on satisfaction, oral and general health-related quality of life: a meta-analysis of randomized controlled trials. Clin Oral Impl Res 2009; 20:533-44.

Qian J, Wennerberg A, Albrektsson T. Reasons for marginal bone loss around oral implants. Clin Implant Dent Relat Res 2012; 14:792-807.

Prapayasatok S, Janhom A, Verochana K, Kasorsri S, Yavirach P. Radiographic evaluation of alveolar bone level around “Fan Yim” implant-retained mandibular overdentures in the Royal dental implant Project. CM Dent J 2013; 34:77-90.

Smith DE, Zarb GA. Criteria for success of osseointegrated endosseous implants. J Prosthet Dent 1989; 62:567-72.

Misch CE, Perel ML, Wang HL, Sammartino G, GalindoMoreno P, Trisi P, et al. Implant success, survival, and failure: the International Congress of Oral Implantologist (ICOI) Pisa Consensus Conference. Implant Dent 2008; 17:5-15.

Albrektsson T, Zarb G, Worthington P, Eriksson AR. The long-term efficacy of currently used dental implants: a review and proposed criteria of success. Int J Oral Maxillofac Implants 1986; 1:11-25.

Downloads

Published

04-01-2021

How to Cite

1.
Leevarakarn S, Wisetsin S, Vichathai W, Nipattasat P, Pakdethanakul C, Khongkhunthian P. Outcomes of Two Implants (Khao Aroi System) Retained Mandibular Overdenture. J DMS [Internet]. 2021 Jan. 4 [cited 2024 Nov. 24];45(3):18-24. Available from: https://he02.tci-thaijo.org/index.php/JDMS/article/view/248571

Issue

Section

Original Article