A Prospective Randomized Controlled Trial on the Study of Mesh Displacement from Fixation and Non-Fixation Method by X-ray Film Assessment after Laparoscopic Total Extraperitoneal Hernia Repair (TEP)

Authors

  • Tantiwattanasirikul P

Keywords:

Inguinal hernia, Laparoscopic, TEP, Mesh fixation, Mesh displacement

References

Poelman MM, van den Heuvel B, Deelder JD, Abis GSA, Beudeker N, Bittner RR, et al. EAES Consensus Development Conference on endoscopic repair of groin hernias. Surg Endosc 2013; 27: 3505-19

Lomanto D, Cheah WK, Faylona JM, Huang CS, Lohsiriwat D, Maleachi A, et al. Inguinal hernia repair: toward Asian guideline. Asian J Endosc Surg 2015; 8:16-23.

Bittner R, Arregui ME, Bisgaard T, Dudai M, Ferzli GS, Fitzgibbons RJ et al. Guidelines for laparoscopic (TAPP) and endoscopic (TEP) treatment of inguinal hernia (International Endohernia Society (IEHS). Surg Endosc 2011;25:2773-843.

Simons MP, Aufenacker T, Bay-Nielsen M, Bouillot JL, Campanelli G, Conze J et al. European Hernia Society guidelines on the treatment of inguinal hernia in adult patients. Hernia 2009; 13: 343-403.

Lichtenstein IL, Shulman AG, Amid PK, Montllor MM. The tension-free hernioplasty. Am J Surg 1989;157:188–93.

Voitk AJ. The learning curve in laparoscopic inguinal hernia repair for the community general surgeon. Can J Surg 1998;41:446–50.

Lawrence K, McWhinnie D, Goodwin A, Gray A, Gordon J, Storie J, et al. An economic evaluation of laparoscopic versus open inguinal hernia repair. J Public Health Med 1996;18:41–8.

Schwab R, Schumacher O, Junge K, Binnebösel M, Klinge U, Becker HP, et al. Biomechanical analyses of mesh fixation in TAPP and TEP hernia repair. Surg Endosc 2008; 22:731–8.

Deans GT, Wilson MS, Royston CM, Brough WA. Recurrent inguinal hernia after laparoscopic repair: possible cause and prevention. Br J Surg1995; 82:539– 41.

Chowbey PK, Bandyopadhyay SK, Sharma A, Khullar R, Soni V, Baijal M. Recurrent hernia following endoscopic total extraperitoneal repair. J Laparoendosc Adv Surg Tech A 2003;13:21-5.

Dion YM, Laplante R, Charara J, Marois M. The influence of the number of endoclips and of mesh incorporation on the strength of an experimental hernia patch repair. Surg Endosc 1994;8:1324-8.

Chevallier JM, Wind P, Lassau JP. Damage to the inguino- femoral nerves in the treatment of hernias. An anatomical hazard of traditional and laparoscopic techniques. Ann Chir 1996;50: 767–75.

Stark E, Oestreich K, Wendl K, Rumstadt B, Hagmüller E. Nerve irritation after laparoscopic hernia repair. Surg Endosc 1999;13:878–81.

Lantis JC 2nd, Schwaitzberg SD. Tack entrapment of the ilioinguinal nerve during laparoscopic hernia repair. J Laparoendosc Adv Surg Tech A 1999;9:285–9.

Taylor C, Layani L, Liew V, Ghusn M, Crampton N, White S. Laparoscopic inguinal hernia repair without mesh fixation, early results of a large randomised clinical trial. Surg Endosc 2008;22:757-62.

Garg P, Nair S, Shereef M, Thakur JD, Nain N, Menon GR, et al. Mesh fixation compared to nonfixation in total extraperitoneal inguinal hernia repair: a randomized controlled trial in a rural center in India. Surg Endosc 2011;25:3300-6.

Tam KW, Liang HH, Chai CY. Outcomes of staple fixation of mesh versus nonfixation in laparoscopic total extraperitoneal inguinal repair: a meta-analysis of randomized controlled trials. World J Surg 2010;34:3065-74.

Claus CM, Rocha GM, Campos AC, Bonin EA, Dimbarre D, Loureiro MP, et al. Prospective, randomized and controlled study of mesh displacement after laparoscopic inguinal repair: fixation versus no fixation of mesh. Surg Endosc 2016;30:1134-40.

Teng YJ, Pan SM, Liu YL, Yang KH, Zhang YC, Tian JH, et al. A meta-analysis of randomized controlled trials of fixation versus nonfixation of mesh in laparoscopic total extraperitoneal inguinal hernia repair. Surg Endosc 2011;25:2849-58.

Beattie GC, Kumar S, Nixon SJ. Laparoscopic total extraperitoneal hernia repair: mesh fixation is unnecessary. J Laparoendosc Adv Surg Tech A2000; 2:71-3.

Ayyaz M, Farooka MW, Malik AA, Khan A, Mansoor R, Toor AA, et al. Mesh fixation vs. non-fixation in total extra peritoneal mesh hernioplasty. J Pak Med Assoc 2015;65:270-2.

Bittner R, Montgomery MA, Arregui E, Bansal V, Bingener J, Bisgaard T, et al. Update of guidelines on laparoscopic (TAPP) and endoscopic (TEP) treatment of inguinal hernia (International Endohernia Society). Surg Endosc 2015;29: 289-321.

Garg P, Rajagopal M, Varghese V, Ismail M. Laparoscopic total extraperitoneal inguinal hernia repair with nonfixation of the mesh for 1,692 hernias. Surg Endosc 2009;23:1241-5.

Sajid MS, Ladwa N, Kalra L, Hutson K, Sains P, Baig MK. A meta-analysis examining the use of tacker fixation versus no-fixation of mesh in laparoscopic inguinal hernia repair. Int J Surg 2012;10:224-31.

Saggar VR, Sarangi R.Laparoscopic totally extraperitoneal repair of inguinal hernia: a policy of selective mesh fixation over a 10-year period. J Laparoendosc Adv Surg Tech A 2008;18:209-12.

Koch CA, Greenlee SM, Larson DR, Harrington JR, Farley DR. Randomized prospective study of totallyextraperitoneal inguinal hernia repair: fixation versus no fixation of mesh. JSLS 2006;10:457-60.

Messaris E, Nicastri G, Dudrick SJ. Total extraperitoneal laparoscopic inguinal hernia repair without mesh fixation: prospective study with 1-year follow-up results. Arch Surg 2010;145:334-8.

Lowham AS, Filipi CJ, Fitzgibbons RJ Jr, Stoppa R, Wantz GE, Felix EL, et al. Mechanisms of hernia recurrence after preperitoneal mesh repair. Traditional and laparoscopic. Ann Surg 1997;225:422–31.

Choy C, Shapiro K, Patel S, Graham A, Ferzli G. Investigating a possible cause of mesh migration during totally extraperitoneal (TEP) repair.Surg Endosc 2004:18:523–5.

Knook MT, van Rosmalen AC, Yoder BE, Kleinrensink GJ, Snijders CJ, Looman CW, et al. Optimal mesh size for endoscopic inguinal hernia repair: a study in a porcine model. Surg Endosc 2001;15:1471–7.

Miserez M, Alexandre JH, Campanelli G, Corcione F, Cuccurullo D, Pascual MH, et al. The European hernia society groin hernia classification: simple and easy to remember. Hernia 2007;11:113-6.

Downloads

Published

01-02-2017

How to Cite

1.
Tantiwattanasirikul P. A Prospective Randomized Controlled Trial on the Study of Mesh Displacement from Fixation and Non-Fixation Method by X-ray Film Assessment after Laparoscopic Total Extraperitoneal Hernia Repair (TEP). J DMS [Internet]. 2017 Feb. 1 [cited 2024 Dec. 23];42(1):79-87. Available from: https://he02.tci-thaijo.org/index.php/JDMS/article/view/248913

Issue

Section

Original Article