ความแม่นยำในการใช้แมมโมแกรม และอัลตราซาวด์ วินิจฉัยมะเร็งเต้านมในโรงพยาบาลนครปฐม
คำสำคัญ:
เอกซเรย์เต้านม, มะเร็งเต้านมบทคัดย่อ
Objectives: To determine the accuracy for detection of breast cancer by mammography and ultrasonography correlate with histopathology and unchanged follow up mammographic reports in 2 years.
Materials and methods: Retrospective study of 2,766 mammographic reports with BI-RADS classification into BI-RADS 1 for negative study, BI-RADS 2 for benign finding, BI-RADS 3 for probably benign lesion, BI-RADS 4 for suspicious malignancy and BI-RADS 5 for highly suggestive of malignancy. All patients had been confirmed diagnosis with tissue histopathology or unchanged mammographic reports up to 2 years.
Results: The overall sensitivity was 91.73%, specificity 98.63% and accuracy 85.86% which are similar to the previous studies.
Conclusion: Mammography with additional sonographic examination is effective screening method for breast cancer.
Downloads
เผยแพร่แล้ว
How to Cite
ฉบับ
บท
License
ลิขสิทธิ์บทความเป็นของผู้เขียนบทความ แต่หากผลงานของท่านได้รับการพิจารณาตีพิมพ์ลงวารสารแพทย์เขต 4-5 จะคงไว้ซึ่งสิทธิ์ในการตีพิมพ์ครั้งแรกด้วยเหตุที่บทความจะปรากฎในวารสารที่เข้าถึงได้ จึงอนุญาตให้นำบทความในวารสารไปใช้ประโยชน์ได้ในเชิงวิชาการโดยจำเป็นต้องมีการอ้างอิงถึงชื่อวารสารอย่างถูกต้อง แต่ไม่อนุญาตให้นำไปใช้ในเชิงพาณิชย์