Comparison of Sperm Motility between The Swim-up and Swim-down Methods
Keywords:
Sperm, Swim-up, Swim-downAbstract
The objective of this study was to compare two methods for the extraction of high motility sperm; the swim-up and swim-down techniques. The result showed that both methods produced greater sperm motility than the original semen. The motility of the sperm was lower in the swim-down method compared with the swim-up method (65.5 ± 11.2% vs 76.5 ± 10.1%; p<0.01).