Comparison of Heart Valve Circumference Examined Before and After 10% Formalin Fixation

Authors

  • Watcharit Anantakal Department of Forensic Medicine, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
  • Somboon Thamtakerngkit Department of Forensic Medicine, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
  • Vijarn Vachirawongsakorn Department of Forensic Medicine, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand

DOI:

https://doi.org/10.33192/Smj.2021.62

Keywords:

Heart valve circumference, formalin fixation

Abstract

Objective: To compare the heart valve circumference before and after 10% formalin fixation.
Materials and Methods: The study analyzed 63 Thai human cadaveric hearts. Each heart valve circumference was separately measured in the fresh state by specifically designed equipment. After that, the hearts were fixed in 10% formalin for 3 days. Then each heart valve circumference was measured by the same equipment and by the thread and ruler technique. The results were analyzed using SPSS package to find the association between the heart valve circumference before and after formalin fixation.
Results: This study showed that the average circumferences of the heart valve measured in the fresh state were 13.329 cm in the tricuspid valve, 10.617 cm in the mitral valve, 8.416 cm in the pulmonic valve, and 7.122 cm in the aortic valve. The average circumferences of the heart valve measured after 10% formalin fixation were 11.019 cm in the tricuspid valve, 8.714 cm in the mitral valve, 6.751 cm in the pulmonic valve, and 6.089 cm in the aortic valve. The average ratios of the heart valve circumference measured fresh and after 10% formalin fixation were 0.8267 in the tricuspid valve, 0.8235 in the mitral valve, 0.8050 in the pulmonic valve, and 0.8573 in the aortic valve. There were significant differences in the heart valve circumference between the fresh state and after formalin fixation (p < 0.001).
Conclusion: This study revealed important information on the dimensional changes of all the formalin-fixed heart valves. We found that the heart valve shrank after formalin fixation, with the formalin-fixed hearts an estimated 0.8 times smaller than the fresh cadaveric hearts.

References

1. Strategy and Planning Division, Office of Permanent Secretary Ministry of Public Health. Public health statistics A.D.2017. Bangkok: Ministry of Public Health; 2017.
2. Chuangsuwanich T, Warnnissorn M, Leksrisakul P, Luksanabunsong P, Thongcharoen P, Sahasakul Y. Pathology and etiology of 154 mitral valve abnormalities surgically removed in Siriraj Hospital. Siriraj Hosp Gaz 2001; 53(8): 481-96.
3. Nkomo VT, Gardin JM, Skelton TN, Gottdiener JS, Scott CG, Enriquez SM. Burden of valvular heart diseases: A population-based study. The Lancet. 2006; 368(9540):1005–11.
4. Brinkley DM, Gelfand EV. Valvular heart disease: classic teaching and emerging paradigms. AM J Med 2013; 126(12): 1035-42.
5. Ilankathir S. A cadaveric study on adult human heart valve annular circumference and its clinical significance. IOSR Journal of Dental and Medical Sciences 2015; 14 (12): 60-64
6. Garg S, Singh P, Sharma A, Gupta G. A gross anatomical study of pulmonary valve in human cadavers. IJMDS. 2014; 3(1): 325-8.
7. Deopujari R, Sinha U, Athavale SA. Anatomy of Left Atrioventricular Valve (Mitral Valve) Leaflets in Adult Indian Cadavers. Int J Morphol 2013; 31(4):1276–81.
8. Jatene MB, Monteiro R, Guimarães MH, Veronezi SC, Koike MK, Jatene FB, et al. Aortic valve assessment: Anatomical study of 100 healthy human hearts. Arq Bras Cardiol 1999; 73(1): 81-6.
9. Gupta C, Shetti VR, Manju BVM. Dimensions of the human adult mitral valve in the embalmed cadaver. J Morphol Sci 2013; 30(1): 6-10.
10. Nayak L, Senapati S, Agrawal D, Mohanty BB, Pattnaik L, Chinara. PK. Morphomeric study of mitral valve of human heart. Research Journal of Pharmaceutical, Biological and Chemical Sciences 2014; 5: 233-8.
11. Westaby S, Karp RB, Blackstone EH, Bishop SP. Adult human valve dimensions and their surgical significance. Am J Cardiol 1984; 53: 552-6.
12. Udhayakumar S, Yasawardene SG. Aortic annular measurements in fresh post-mortem heart: a study in Sri Lankans. Ceylon Medical Journal 2015; 60: 148-51.
13. Lama CP, Pradhan A, Chalise U, Dhungel S, Ghosh SK. Measurement of the tricuspid and the mitral valve in adult human heart: a cadaveric study. Nepal Med Coll J 2018; 20(4): 121-7.
14. Skwarek M, Hreczecha J, Dudziak M, Grzybiak M. The morphology of the right atrioventricular valve in the adult human heart. Folia Morphol 2006; 65(3): 200-8.
15. Tei C, Pilgrim JP, Shah PM, Ormiston JA, Wong M. The tricuspid valve annulus: study of size and motion in normal subjects and in patients with tricuspid regurgitation. Circulation 1982; 66(3): 665-71.
16. Chen CH, Hsu MY, Jiang RS, Wu SH, Chen FJ, Liu SA. Shrinkage of head and neck cancer specimens after formalin fixation. Journal of the Chinese Medical Association 2012; 75(3): 109-13.
17. Pritt B, Tessitore JJ, Weaver DL, Blaszyk H. The effect of tissue fixation and processing on breast cancer size. Hum Pathol 2005; 36: 756-60.
18. Jonmarker S, Valdman A, Lindberg A, Hellström M, Egevad L. Tissue shrinkage after fixation with formalin injection of prostatectomy specimens. Virchows Arch 2007; 84: 1825-9.
19. Hsu PK, Huang HC, Hsieh CC, Hsu HS, Wu YC, Huang MH, et al. Quantification of surgical margin shrinkage in the oral cavity. Head Neck 1997; 19: 281-6.
20. Yeap BH, Muniandy S, Lee SK, Sabaratnam S, Singh M. Specimen shrinkage and its influence on margin assessment in breast cancer. Asian J Surg 2007; 30: 183-7.
21. Rooban T, Vidya KM, Joshua E, Umadevi KR, Kannan R. Chemical and physical basics of routine formaldehyde fixation. Journal of Oral and Maxillofacial Pathology 2012; 16(3): 400-5.
22. Dempster WT. Rate of penetration of fixing fluids. Am J Anat. 1960; 107: 59-72.
23. Alison MP, Mathieu V, Jeremy RM, Giovanni F, Benjamin MJ, Chandra MS, Paul AY, Robert CG, and Joseph H. Statistical assessment of normal mitral annular geometry using automated three-dimensional echocardiographic analysis. The Society of Thoracic Surgeons 2014; 97: 71-7.

Published

01-07-2021

How to Cite

Anantakal, W. ., Thamtakerngkit, S. ., & Vachirawongsakorn, V. . (2021). Comparison of Heart Valve Circumference Examined Before and After 10% Formalin Fixation. Siriraj Medical Journal, 73(7), 478–484. https://doi.org/10.33192/Smj.2021.62

Issue

Section

Original Article