Survey of mean glandular in mammography practice in hospitals in central Region of Thailand

Authors

  • Anong Singkavongsay Bureau of Radiation and Medical Devices, Department of Medical Sciences

Keywords:

Entrance Surface Air Kerma, (ESAK), Average Glandular Dose: AGD, mammogram

Abstract

       Survey of mammography practice in the hospitals in region of Thailand following the International Code of Practices recommended by IAEA to check quality of Mammogram X-ray unit that consists of two components including control of the quality of radiographic by using the PMMA Phantom and ACR Mammo Phantom, density 4.5 cm. as well as measuring tube loading output Entrance Skin Air Kerma (ESAK) In mGy/mAs unit and HVL (Half value layer) by using the calibrated X-ray machine. Hospital’s officers have to record the data of breast radiograph. The focus to film distance or image and patient’s breast thickness were used to calculate Average Glandular dose (AGD). From the survey of Mammogram X-ray showed that the kVp used was between 25-29 kVp, the mA x time in the exposure was between 55-176 mAs, and the focus to film distance was between 56-65 cm. The patients’ breast thickness was between 3.6-6.9 cm and the age of patients was between 40-60 years old. It was found that the AGD was 2.5 mGy which was not more than the reference value recommended by IAEA (3 mGy) but the ESAK was 12.9 mGY which was higher than the reference value of IAEA (11 mGy)

References

International Atomic Energy Agency. Dosimetry in Diagnostic Radiology: An International Code of Practice. Technical Reports Series No.457. Vienna, Austria: IAEA; 2007.

International Atomic Energy Agency . Quality Assurance Programme for Screen Film Mammagraphy: IAEA Human Health Series No.2. Vienna, Austria: IAEA; 2009.

American Association of Physicists in Medicine. Standardize method for measuring diagnostic x-ray exposures, AAPM Report No.31. New York: American Institute of Physics; 1991.

Dance DR. Monte Carlo calculation of conversion factors for the estimation of mean glandular breast dose. Phys Med Biol 1990; 35: 1211-9.

Kristien Smans, Hilde Bosmans, Ann-Katherine Carton, Mu Xiao, Dose reference values for (digital) mammography Guy Marchal Leuvens Universitair Centrum van Medische Fysica in de Radiologie Universitaire Ziekenhuizen van de KU Leuven

Downloads

Published

31-03-2016

How to Cite

1.
Singkavongsay A. Survey of mean glandular in mammography practice in hospitals in central Region of Thailand. ว กรมวิทย พ [internet]. 2016 Mar. 31 [cited 2026 Sep. 8];58(1):33-8. available from: https://he02.tci-thaijo.org/index.php/dmsc/article/view/241713

Issue

Section

Original Articles