The study of factors and guidelines for reducing image retake rate in digital radiography of chest PA upright and knee lateral standing at Songklanakarin Hospital

Authors

  • Watcharakorn Panniam Radiological Technology Program, Department of Radiology, Faculty of Medicine, Prince of Songkla University
  • Pongpol Limpornwichian Radiological Technology Program, Department of Radiology, Faculty of Medicine, Prince of Songkla University
  • Natee Ina Radiological Technology Program, Department of Radiology, Faculty of Medicine, Prince of Songkla University
  • Jongwat Cheewakul Radiological Technology Program, Department of Radiology, Faculty of Medicine, Prince of Songkla University
  • Seri Sakjirapapong Department of Radiology, Faculty of Medicine, Prince of Songkla University

Keywords:

Image retake rate, Digital radiography, Chest PA upright, Knee lateral standing

Abstract

The purposes of this study were to know the factors and guidelines for reducing image retake rate in Digital Radiography of Chest PA Upright and Knee Lateral Standing by radiologic technologists at Songklanakarind Hospital. This project is Cross-Sectional Analysis Study. we studied about the factors that effect to image retake rate from the Reject and Usage Analysis Tool program. we collected the data before guidelines one month for analysis. After that, we made the guidelines, and collected the data after guidelines one month. we brought data two months to compare. As a result of data analysis before making guidelines, we found that the number of top three images retake separated by body part were Chest (18.93%), Knee (17.46%) and Abdomen (8.63%) respectively. The reasons for reject of Chest were Positioning/Breathing (66.67%), Other reasons (14.18%), Foreign Material/Artifacts (9.93%), Patient Motion (8.51%) and Position by Orthopedics (0.71%). The reasons for reject of Knee were Positioning (52.65%), Patient Motion (22.86%), Position by Orthopedics (10.61%), Other reasons (8.98%), Foreign Material (2.86%) and X-ray system failure (2.04%). The image retake rate of Chest PA Upright before making the guideline was 1.96%, after making the guideline was 2.48%. The image retake rate of Knee Lateral Standing, before making the guideline was 17.11%, after making the guideline was 16.10%. It showed that, the image retake rate of Knee Lateral Standing reduced but Chest PA Upright didn’t reduce.

Downloads

Download data is not yet available.

References

Hall EJ, Giaccia AJ. Radiobiology for the Radiologist. Vol. 6. Lippincott Williams & Wilkins Philadelphia; 2006.

Lin C-S, Chan P-C, Huang K-H, et al. Guidelines for reducing image retakes of general digital radiography Advances in Mechanical Engineering 2016;8:1687814016644127.

Nol J, Isouard G, Mirecki J. Digital repeat analysis; setup and operation. Journal of digital imaging 2006;19:159.

Roohi Shalemaei R. Films reject analysis for conventional radiography in Iranian main hospitals. Radiation protection dosimetry 2011;147:220–222.

Hofmann B, Rosanowsky TB, Jensen C, et al. Image rejects in general direct digital radiography. Acta Radiologica Short Reports 2015;4:2058460115604339.

Downloads

Published

2019-12-25

How to Cite

1.
Panniam W, Limpornwichian P, Ina N, Cheewakul J, Sakjirapapong S. The study of factors and guidelines for reducing image retake rate in digital radiography of chest PA upright and knee lateral standing at Songklanakarin Hospital. Thai J Rad Tech [Internet]. 2019 Dec. 25 [cited 2024 Dec. 5];44(1):45-52. Available from: https://he02.tci-thaijo.org/index.php/tjrt/article/view/246757

Issue

Section

Original articles