The Cost Effectiveness of Applied Method for Detecting Antigen-D in Donated Blood Using Slide Technique and Dilutedanti-D solution

Main Article Content

Sutinee Jansuwan

Abstract

Background: Application of the detection of antigen D by slide method, which is made from Formica plates 30 x 40 cm with 90 com partments for mass testing. Using anti-D solution to reduce costs and time.
Objective: This study aimed to examine the effect of using slide technique along with diluted anti-D solution, an applied method, to detect
antigen-D.
Setting: Nan Hospital, Nan Province
Design: Diagnostic test
Methods: A total of 8,396 donated blood samples in Blood Bank Department, Nan Hospital, were recruited during March and August 2019.The slide technique in combination with diluted 1:16 anti-D solution with red cell by stick method and the test results were interpreted with naked eyes. If the negative result was shown, the standard test tube technique would beapplied to confirm by Indirect AntiglobulinTest (IAT) whether blood sample was Rh negative or weak D.
Results: The findings of this study revealed that an applied technique illustrated the positive result (Rh positive) in 8,375 blood specimens (99.75%) and the negative result in 21 specimens (0.25%). The confirmation method using indirect antiglobulin test to identify 21 specimens with the negative result indicated that all were Rh negtive.
Conclusion: Detecting antigen-D by using the slide technique and diluted anti-D solution prvides similar end result when compared with the standard test. Moreover, this applied technique is cost-effective and save time, especially when having a number of donated blood samples needed to be tested at the same time.
Keywords: antigen D, diluted anti-D, solution

Downloads

Download data is not yet available.

Article Details

Section
Original Articles

References

1. Fongsarun J, Nuchprayoon I, Yod-in S, Kupatawintu P, Kidprasirt C. Blood groups in Thai blood donors. Thai J HematoTransfus Med 2002;12:278-86.

2. Roback JD, Combs MR, Grossman BJ, Hillyer CD, editors. Technical manual. 16th.ed. Bethesda: American Association of Blood Banks, 2008.

3. Harmening DM. Modern blood banking & transfusion practices. 5th ed. Philadelphia: F.A. Davis Company, 2005.

4. Avent ND, Reid ME.The Rh blood group system: a review. Blood 2000;95(2):375-87.

5. Anderson HJ, Patel S.Red cell phenotyping using hexadimethrine bromide (Polybrene) in a microplate system. Transfusion 1984;24(4):353-6.

6. Dixon MR. Microplate: a flexible system for serologic testing. In: Myerds M, Reynolds A,editors. Micro method in blood group serology. Arlington: American Association of Blood Banks, 1984:376-9.

7 .อมรรัตน์ ร่มพฤกษ์, ยุพา เอื้อวิจิตรอรุณ, ชาญวิทย์ ลีลายุวัฒน์, มาลินี มีแสง. การดัดแปลงเทคนิคไมโครเพลทเพื่อใช้ตรวจหาแอนติเจน D. วารสารเทคนิคการแพทย์ 2535;20:123-7.

8. มาลินี มีแสง. การใช้เทคนิคไมโครเพลทตรวจหาแอนติเจนอาร์เอชดีโดยใช้แอนติ-ดีเจือจางทำปฏิกิริยาในน้ำเกลือปกติ. ศรีนครินทร์เวชสาร 2540;12(4):207-11.

9. พัฒน์ศิริอังกสิทธิ์,สมเชษฐ์ เดชะพันธ์,ยศธร จงศิริกุล, ปราโมทย์ ศรีวาณิชรักษ์,มานิดา เศรษฐการ, สิณีนาฏ อุทาและคณะ. การตรวจแอนติเจน D ของหมู่เลือดระบบ Rh ด้วยวิธีไมโครเพลท. วารสารโลหิตวิทยาและเวชศาสตร์บริการโลหิต 2554;21(1):15-21.

10. สหวัฒน์ บรัศว์รักษ์, บรรณาธิการ. เทคนิคพื้นฐานที่ใช้ในห้องปฏิบัติการทางคลังเลือด คู่มือปฏิบัติการคลังเลือด. พิมพ์ครั้งที่ 4. ขอนแก่น : ภาควิชาภูมิคุ้มกันวิทยาคลินิก คณะเทคนิคการแพทย์ มหาวิทยาลัยขอนแก่น; 2535.